2 Ton RO Plant

2-ton-ro-plant-1-20211123124200.jpg

2 Ton RO Plant


2000 LPH (or) 12000 GPD RO / Model -LKT-2TRO 3P

Reverse Osmosis System is mainly used in Drinking Water Factory. Reverse Osmosis System 97%-99% Salt Rejection and Permeate Flow Rate is 2000 LPH (or) 12000 GPD. Produce High Pure Water with Lower concentration of T.D.S. Both of Single Phase and 3 Phase are available. Instrument Control System is set up with Electrical Relay Control and PLC/MCU.

Include RO Membrane Protection System. Build in check valve to protect RO Membrane back pressure. Flow Meter and Pressure Gauges are also involved in RO plant. Protection Control System is installed for Vertical High Pressure Pump.

Inquiry Now

Overview

  • Flow Rate - 2000 LPH
  • Operation Type - Manual (Emergency On/Off and Manual Control Function include)
  • Power - 220V, 50 Hz, 3kW – 4kW
  • Electrical Control Type - Relay and Timer or PLC
  • Filtration Stage - 2 Stages Filtration
  • Our team supplies full line of standard and customizable design. We build any Type of RO System for water treatment application.

Components

  • 5 Micron Cartridge Filter
    • Quantity - 1 Set
    • Material - UPVC (or) Steel
    • No of Vessel - 5
  • Vertical Multi Stage High Pressure and RO Membrane depend on raw water quality and product water quality
  • High Pressure Switch
  • Low Pressure Switch
  • High Level and Low Level Switch
  • T.D.S Sensor and Monitor (Permeate)
  • Feed High Pressure Switch and Indicator
  • Product and Reject Flow Meter
  • pH and Water Quality Control (user optional)
  • Electrical Control Panel (Relay/PLC / MCU Type)
  • Adjust Recovery Rate
  • Product Water Sample Tap
  • Pressure Gauge
  • Emergency Stop Function and Reset Function
  • Indication Lamp for all state of RO
  • UPVC for High Pressure Pump piping
  • SS-304 Steel Frame

Specification

  • Max Feed Water temperature ~ 42°C
  • Feed water pressure ~ 20psi-50psi
  • Operation Pressure ~ 150 Psi - 400 Psi
  • Turbidity should be remove
  • H2S , Turbidity and Organics must be removed
  • Max Iron Content ~ 0.05 ppm
  • Feed Water T.D.S ~ 200-5000 ppm
  • Equipment upgrade For T.D.S over 5000 ppm
  • pH tolerance range ~ 3-11
  • Biological or Organics content must be removed

Application

Can be use in process water and drinking water factory. RO unit design depends on raw water quality and product water quality.

Service & Maintenance

  • We can operate maintenance task on any water treatment technology within our scope of supply.
  • Please do not hesitate to contact us for maintenance on your old equipment.

Installation

  • We supervise installation and commission every single unit we provide, on client's request.
  • We check and maintain our Machine and Water Treatment Solution 1 Time in 2 months.